
产品介绍
产品信息
宿主
无

商品描述
Superose 6 Increase small-scale SEC columns
Size exclusion chromatography columns: for high-resolution protein purification and analysis in MW range Mr~ 5K to ~ 5M.Superose 6 Increase SEC columns are designed for high-resolution, small-scale preparative purification, and analysis of large globular proteins, protein complexes, and other macromolecules in the molecular weight range Mr~ 5K to ~ 5M.
Wide fractionation range: optimized to purify large biomolecules, including membrane proteins, protein complexes, and DNA fragments
Very high resolution: small bead size and a narrow particle size distribution provide high resolution, for high protein purity
High flow rates: rigid beads give excellent pressure/flow properties
Enhanced performance: improved resolution and runtime compared to predecessor
“Increase”: Cytiva's new generation of size exclusion chromatography columns
Superose 6 Increase is a next-generation, agarose-based matrix for size exclusion chromatography. With smaller and more rigid beads than their predecessors, Superose 6 Increase columns deliver higher resolution protein purification in shorter runtimes.
Fractionation of large proteins and protein complexes
Suitable for both preparative and analytical applications, Superose 6 Increase SEC columns are the first choice for the characterization of large proteins and protein complexes. They can also be used the study of protein-protein interactions, and as a screening tool to explore the molecular weight distribution of an unknown sample.
Superose 6 and Superdex 200 analysis ranges are complementary
Superose 6 Increase is designed for separation of protein complexes and other very large molecules, including those with molecular weights exceeding Mr ~400 000. The optimal fractionation range of Superdex 200 Increase is complementary, providing higher resolution for proteins with molecular weights below Mr ~400 000.
Cleaning-in-place (CIP) capabilities
This agarose-based resin is alkali resistant and supports cleaning-in-place (CIP) procedures. This capability allows the same column to be used for different proteins, with minimal risk of carry-over between samples.
Regular cleaning can also increase column lifetime.
Choose from 3 column sizes to suit varying application needs
Column Recommended sample volume Recommended operating flow Efficiency (N/m) Applications
Superose 6 Increase 3.2/300 4 to 50 µL 0.04 mL/min >48,000 Small-scale preparative purification and analysis of large proteins and other biomolecules, when small sample and buffer consumption is important
Superose 6 Increase 10/300 GL 25 to 500 µL 0.5 mL/min > 48,000 Standard for small-scale preparative purification and analysis of large proteins and other biomolecules, especially protein complexes
Superose 6 Increase 5/150 GL 4 to 50 µL 0.3 mL/min > 42,000 Rapid purity check and homogeneity analysis of large proteins and protein complexes
Feedback on Superose 6 Increase SEC columns
"Now I can work on more samples, resulting in higher throughput. I can now purify a protein in 30 minutes instead of an hour." Dr. Tomohiro Nishizawa (Nureki Laboratory). Department of Biological Sciences, Graduate School of Science, The University of Tokyo
Successful use in published research
Researchers use these pre-packed columns for a variety of applications, such as:
Study of a magnetic sensing protein
Evaluation of effects two proteins have on microtubule nucleation
Production of virus-like particles in E. coli

形状
液体

颜色
白色不透明

组成成分
无

背景
CAS号
64-17-5

声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。