PE-CF594 Annexin V(Annexin V)
1/2

PE-CF594 Annexin V(Annexin V)

分享
品牌: BD Pharmingen
pdf 下载产品说明书
用小程序,查商品更便捷
收藏
对比对比
咨询咨询
    反应种属:
    Human (QC Testing)
    Human (QC Testing)
    实验应用:
    Flow cytometry (Routinely Tested)
    Flow cytometry (Routinely Tested)
    产品介绍
    产品信息
    耦联标记
    PE-CF594
    抗原名称
    ANNEXIN V
    简单描述
    Apoptosis is a normal physiologic process that occurs during embryonic development as well as in maintenance of tissue homeostasis. The apoptotic program is characterized by certain morphologic features, including loss of plasma membrane asymmetry and attachment, condensation of the cytoplasm and nucleus, and internucleosomal cleavage of DNA. Loss of plasma membrane asymmetry is one of the earliest features. In apoptotic cells, the membrane phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma membrane, thereby exposing PS to the external cellular environment. Annexin V is a 35-36 kDa Ca2+ dependent phospholipid-binding protein that has a high affinity for PS, and binds to cells with exposed PS. Annexin V may be conjugated to fluorochromes including BD Horizon™ PE-CF594. This format retains its high affinity for PS and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, PE-CF594 Annexin V staining can identify cells undergoing apoptosis at an earlier stage rather than assays based on nuclear changes such as DNA fragmentation. PE-CF594 Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either apoptotic or necrotic processes. Therefore, staining with PE-CF594 Annexin V is typically used in conjunction with a vital dye such as 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (PE-CF594 Annexin V positive, 7-AAD negative). Viable cells with intact membranes exclude 7-AAD, whereas the membranes of dead and damaged cells are permeable to the nucleic acid dye, 7-AAD.  For example, cells that are considered viable are both PE-CF594 Annexin V negative and 7-AAD negative while cells that are in early apoptosis are PE-CF594 Annexin V positive and 7-AAD negative. Cells that are in late apoptosis or already dead are both PE-CF594 Annexin V positive and 7-AAD positive. This assay does not distinguish between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead cells will stain with both PE-CF594 Annexin V and 7-AAD. However, when apoptosis is measured over time, cells can be often tracked from being PE-CF594 Annexin V negative and 7-AAD negative (viable, or no measurable apoptosis), to PE-CF594 Annexin V positive and 7-AAD negative (early apoptosis, membrane integrity is present), and finally to PE-CF594 Annexin V positive and 7-AAD positive (end stage apoptosis and death). The movement of cells through these three stages suggests apoptosis. In contrast, a single observation indicating that cells are both PE-CF594 Annexin V and 7-AAD positive, by itself reveals less information about the process by which the cells underwent their demise. The Annexin V is conjugated to BD Horizon PE-CF594 that has been developed for use in multicolor flow cytometry experiments and is available exclusively from BD Biosciences. Annexin is conjugated to BD Horizon PE-CF594, which has been developed exclusively by BD Biosciences as a better alternative to PE-Texas Red®. PE-CF594 excites and emits at similar wavelengths to PE-Texas Red® yet exhibits improved brightness and spectral characteristics. Due to PE having maximal absorption peaks at 496 nm and 564 nm, PE-CF594 can be excited by the blue (488-nm), green (532-nm) and yellow-green (561-nm) lasers and can be detected with the same filter set as PE-Texas Red® (eg, 610/20-nm filter). When compensating dyes in this spectral range, the most accurate compensation can be obtained using unstained and single color-stained cellular controls.
    商品描述
    Apoptosis is a normal physiologic process that occurs during embryonic development as well as in maintenance of tissue homeostasis. The apoptotic program is characterized by certain morphologic features, including loss of plasma membrane asymmetry and attachment, condensation of the cytoplasm and nucleus, and internucleosomal cleavage of DNA. Loss of plasma membrane asymmetry is one of the earliest features. In apoptotic cells, the membrane phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma membrane, thereby exposing PS to the external cellular environment. Annexin V is a 35-36 kDa Ca2+ dependent phospholipid-binding protein that has a high affinity for PS, and binds to cells with exposed PS. Annexin V may be conjugated to fluorochromes including BD Horizon™ PE-CF594. This format retains its high affinity for PS and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, PE-CF594 Annexin V staining can identify cells undergoing apoptosis at an earlier stage rather than assays based on nuclear changes such as DNA fragmentation. PE-CF594 Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either apoptotic or necrotic processes. Therefore, staining with PE-CF594 Annexin V is typically used in conjunction with a vital dye such as 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (PE-CF594 Annexin V positive, 7-AAD negative). Viable cells with intact membranes exclude 7-AAD, whereas the membranes of dead and damaged cells are permeable to the nucleic acid dye, 7-AAD.  For example, cells that are considered viable are both PE-CF594 Annexin V negative and 7-AAD negative while cells that are in early apoptosis are PE-CF594 Annexin V positive and 7-AAD negative. Cells that are in late apoptosis or already dead are both PE-CF594 Annexin V positive and 7-AAD positive. This assay does not distinguish between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead cells will stain with both PE-CF594 Annexin V and 7-AAD. However, when apoptosis is measured over time, cells can be often tracked from being PE-CF594 Annexin V negative and 7-AAD negative (viable, or no measurable apoptosis), to PE-CF594 Annexin V positive and 7-AAD negative (early apoptosis, membrane integrity is present), and finally to PE-CF594 Annexin V positive and 7-AAD positive (end stage apoptosis and death). The movement of cells through these three stages suggests apoptosis. In contrast, a single observation indicating that cells are both PE-CF594 Annexin V and 7-AAD positive, by itself reveals less information about the process by which the cells underwent their demise. The Annexin V is conjugated to BD Horizon PE-CF594 that has been developed for use in multicolor flow cytometry experiments and is available exclusively from BD Biosciences. Annexin is conjugated to BD Horizon PE-CF594, which has been developed exclusively by BD Biosciences as a better alternative to PE-Texas Red®. PE-CF594 excites and emits at similar wavelengths to PE-Texas Red® yet exhibits improved brightness and spectral characteristics. Due to PE having maximal absorption peaks at 496 nm and 564 nm, PE-CF594 can be excited by the blue (488-nm), green (532-nm) and yellow-green (561-nm) lasers and can be detected with the same filter set as PE-Texas Red® (eg, 610/20-nm filter). When compensating dyes in this spectral range, the most accurate compensation can be obtained using unstained and single color-stained cellular controls.
    克隆号
    Annexin V
    产品详情
    PE-CF594
    BD Horizon™ PE-CF594 dye is a part of the BD PE family of dyes. This tandem fluorochrome is comprised of a R-Phycoerythrin (PE) donor that has excitation maxima (Ex Max) of 496-nm and 566-nm and an acceptor dye with an emission maximum (Em Max) at 615-nm. PE-CF594, driven by BD innovation, is designed to be excited by the blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and detected using an optical filter centered near 615 nm (e.g., a 610/20-nm bandpass filter). The donor dye can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and the acceptor dye can be excited by the green (532-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
    PE-CF594
    Yellow-Green 488 nm, 532 nm, 561 nm
    496 nm, 566 nm
    615 nm
    应用
    实验应用
    Flow cytometry (Routinely Tested)
    推荐用量
    5 µl
    反应种属
    Human (QC Testing)
    制备和贮存
    存储溶液
    Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
    保存方式
    Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
    文献
    文献
    研发参考(8) 1. Andree HA, Reutelingsperger CP, Hauptmann R, Hemker HC, Hermens WT, Willems GM. Binding of vascular anticoagulant alpha (VAC alpha) to planar phospholipid bilayers. J Biol Chem. 1990; 265(9):4923-4928. (Biology). 2. Casciola-Rosen L, Rosen A, Petri M, Schlissel M. Surface blebs on apoptotic cells are sites of enhanced procoagulant activity: implications for coagulation events and antigenic spread in systemic lupus erythematosus. Proc Natl Acad Sci U S A. 1996; 93(4):1624-1629. (Methodology: Apoptosis, Flow cytometry). 3. Homburg CH, de Haas M, von dem Borne AE, Verhoeven AJ, Reutelingsperger CP, Roos D. Human neutrophils lose their surface Fc gamma RIII and acquire Annexin V binding sites during apoptosis in vitro. Blood. 1995; 85(2):532-540. (Biology). 4. Koopman G, Reutelingsperger CP, Kuijten GA, Keehnen RM, Pals ST, van Oers MH. Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis. Blood. 1994; 84(5):1415-1420. (Methodology: Apoptosis, Flow cytometry). 5. Martin SJ, Reutelingsperger CP, McGahon AJ, et al. Early redistribution of plasma membrane phosphatidylserine is a general feature of apoptosis regardless of the initiating stimulus: inhibition by overexpression of Bcl-2 and Abl. J Exp Med. 1995; 182(5):1545-1556. (Biology). 6. Raynal P, Pollard HB. Annexins: the problem of assessing the biological role for a gene family of multifunctional calcium- and phospholipid-binding proteins. Biochim Biophys Acta. 1994; 1197(1):63-93. (Biology). 7. Vermes I, Haanen C, Steffens-Nakken H, Reutelingsperger C. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled Annexin V. J Immunol Methods. 1995; 184(1):39-51. (Methodology: Apoptosis, Flow cytometry). 8. van Engeland M, Ramaekers FC, Schutte B, Reutelingsperger CP. A novel assay to measure loss of plasma membrane asymmetry during apoptosis of adherent cells in culture. Cytometry. 1996; 24(2):131-139. (Methodology: Apoptosis, Flow cytometry).

    参考图片

    声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。
    货号:
    563544
    一键复制
    询价
    50Tst
    选择数量
    当前规格1件起购 
    配送至