


1/4

品牌: BD Pharmingen








产品介绍
产品信息
抗原名称
CD4

简单描述
The Mouse CD4 Fluorochrome Evaluation Kit includes a 10 µg Evaluation Sample of the following components:
• Alexa Fluor® 488 Rat Anti-Mouse CD4 RM4-5
• BV480 Rat Anti-Mouse CD4 RM4-5
• Alexa Fluor® 647 Rat Anti-Mouse CD4 RM4-5
• BV510 Rat Anti-Mouse CD4 RM4-5
• Alexa Fluor® 700 Rat Anti-Mouse CD4 RM4-5
• BV605 Rat Anti-Mouse CD4 RM4-5
• APC Rat Anti-Mouse CD4 RM4-5
• BUV615 Rat Anti-Mouse CD4 GK1.5
• APC-Cy™7 Rat Anti-Mouse CD4 RM4-5
• BV650 Rat Anti-Mouse CD4 RM4-5
• APC-H7 Rat Anti-Mouse CD4 GK1.5
• BV711 Rat Anti-Mouse CD4 RM4-5
• APC-R700 Rat Anti-Mouse CD4 RM4-5*
• BV786 Rat Anti-Mouse CD4 RM4-5
• BB515 Rat Anti-Mouse CD4 GK1.5 *
• FITC Rat Anti-Mouse CD4 RM4-5
• BB700 Rat Anti-Mouse CD4 RM4-5
• PE Rat Anti-Mouse CD4 RM4-5
• BUV395 Rat Anti-Mouse CD4 GK1.5
• PE-CF594 Rat Anti-Mouse CD4 RM4-5
• BUV496 Rat Anti-Mouse CD4 GK1.5
• PE-Cy™5 Rat Anti-Mouse CD4 RM4-5
• BUV563 Rat Anti-Mouse CD4 GK1.5
• PE-Cy™7 Rat Anti-Mouse CD4 RM4-5
• BUV661 Rat Anti-Mouse CD4 RM4-5 *
• PerCP-Cy™5.5 Rat Anti-Mouse CD4 RM4-5
• BUV737 Rat Anti-Mouse CD4 RM4-5
• V450 Rat Anti-Mouse CD4 RM4-5
• BUV805 Rat Anti-Mouse CD4 GK1.5
• V500 Rat Anti-Mouse CD4 RM4-5
• BV421 Rat Anti-Mouse CD4 GK1.5
• R718 Rat Anti-Mouse CD4 RM4-5
• RY586 Rat Anti-Mouse CD4 GK1.5
• RB780 Rat Anti-Mouse CD4 GK1.5
• RB545 Rat Anti-Mouse CD4 GK1.5
To access the Technical Data Sheet (TDS) for individual conjugates, search the name of the clone and/or the specificity on the website: http://www.bdbiosciences.com
.
Fluorochrome brightness is representative of the specific Anti-Mouse CD4 clone, other clones may differ. As for all tandem reagents, spillover values should not be assumed to be identical for other clones
.
The reagents in this kit are to be used for instrument set-up and not immunophenotyping, therefore reagents distinguished with an asterisk symbol are not available as single vial catalogue products but can be made available as a custom product
.
Please note that the following dyes are detected in the same channel. To access the Absorption and Emission Spectra for each individual fluorochrome, go to: https://www.bdbiosciences.com/en-us/resources/bd-spectrum-viewer
• FITC, BB515 and RB545
• V450 and BV421
• V500, BV510, BV480
• BB700 and PerCP-Cy5.5
• APC-Cy7 and APC-H7
• APC-R700, Alexa Fluor 700, and R718
• PE and RY586
• PE-Cy7 and RB780 (when using blue laser)

商品描述
The Mouse CD4 Fluorochrome Evaluation Kit includes a 10 µg Evaluation Sample of the following components:
• Alexa Fluor® 488 Rat Anti-Mouse CD4 RM4-5
• BV480 Rat Anti-Mouse CD4 RM4-5
• Alexa Fluor® 647 Rat Anti-Mouse CD4 RM4-5
• BV510 Rat Anti-Mouse CD4 RM4-5
• Alexa Fluor® 700 Rat Anti-Mouse CD4 RM4-5
• BV605 Rat Anti-Mouse CD4 RM4-5
• APC Rat Anti-Mouse CD4 RM4-5
• BUV615 Rat Anti-Mouse CD4 GK1.5
• APC-Cy™7 Rat Anti-Mouse CD4 RM4-5
• BV650 Rat Anti-Mouse CD4 RM4-5
• APC-H7 Rat Anti-Mouse CD4 GK1.5
• BV711 Rat Anti-Mouse CD4 RM4-5
• APC-R700 Rat Anti-Mouse CD4 RM4-5*
• BV786 Rat Anti-Mouse CD4 RM4-5
• BB515 Rat Anti-Mouse CD4 GK1.5 *
• FITC Rat Anti-Mouse CD4 RM4-5
• BB700 Rat Anti-Mouse CD4 RM4-5
• PE Rat Anti-Mouse CD4 RM4-5
• BUV395 Rat Anti-Mouse CD4 GK1.5
• PE-CF594 Rat Anti-Mouse CD4 RM4-5
• BUV496 Rat Anti-Mouse CD4 GK1.5
• PE-Cy™5 Rat Anti-Mouse CD4 RM4-5
• BUV563 Rat Anti-Mouse CD4 GK1.5
• PE-Cy™7 Rat Anti-Mouse CD4 RM4-5
• BUV661 Rat Anti-Mouse CD4 RM4-5 *
• PerCP-Cy™5.5 Rat Anti-Mouse CD4 RM4-5
• BUV737 Rat Anti-Mouse CD4 RM4-5
• V450 Rat Anti-Mouse CD4 RM4-5
• BUV805 Rat Anti-Mouse CD4 GK1.5
• V500 Rat Anti-Mouse CD4 RM4-5
• BV421 Rat Anti-Mouse CD4 GK1.5
• R718 Rat Anti-Mouse CD4 RM4-5
• RY586 Rat Anti-Mouse CD4 GK1.5
• RB780 Rat Anti-Mouse CD4 GK1.5
• RB545 Rat Anti-Mouse CD4 GK1.5
To access the Technical Data Sheet (TDS) for individual conjugates, search the name of the clone and/or the specificity on the website: http://www.bdbiosciences.com
.
Fluorochrome brightness is representative of the specific Anti-Mouse CD4 clone, other clones may differ. As for all tandem reagents, spillover values should not be assumed to be identical for other clones
.
The reagents in this kit are to be used for instrument set-up and not immunophenotyping, therefore reagents distinguished with an asterisk symbol are not available as single vial catalogue products but can be made available as a custom product
.
Please note that the following dyes are detected in the same channel. To access the Absorption and Emission Spectra for each individual fluorochrome, go to: https://www.bdbiosciences.com/en-us/resources/bd-spectrum-viewer
• FITC, BB515 and RB545
• V450 and BV421
• V500, BV510, BV480
• BB700 and PerCP-Cy5.5
• APC-Cy7 and APC-H7
• APC-R700, Alexa Fluor 700, and R718
• PE and RY586
• PE-Cy7 and RB780 (when using blue laser)

文献
文献
研发参考(3)
1. Bierer BE, Sleckman BP, Ratnofsky SE, Burakoff SJ. The biologic roles of CD2, CD4, and CD8 in T-cell activation. Annu Rev Immunol. 1989; 7:579-599. (Biology).
2. Janeway CA Jr. The T cell receptor as a multicomponent signalling machine: CD4/CD8 coreceptors and CD45 in T cell activation. Annu Rev Immunol. 1992; 10:645-674. (Biology).
3. Wu L, Scollay R, Egerton M, Pearse M, Spangrude GJ, Shortman K. CD4 expressed on earliest T-lineage precursor cells in the adult murine thymus. Nature. 1991; 349(6304):71-74. (Biology).

参考图片
声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。