1/2

品牌: BD Pharmingen









反应种属:
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
来源宿主:
Mouse BALB/c IgG1, κ
Mouse BALB/c IgG1, κ
产品介绍
产品信息
耦联标记
PE

抗原名称
CD86 (B7-2)

宿主
Mouse BALB/c IgG1, κ

免疫原
Human HBL-1 Cell Line

简单描述
The 2331 (FUN-1) monoclonal antibody specifically recognizes a 75 kDa transmembrane cell surface protein, CD86 (B70/B7-2), expressed primarily on monocytes, dendritic cells and activated B cells. Competitive binding assays demonstrate that, while both 2331 (FUN-1) and IT2.2 (Anti-CD86) antibodies specifically recognize the same molecule, they react with different epitopes. CD86 is a ligand for CD28 and CTLA-4 and plays an important role in costimulation of T cells in primary immune response. The 2331 (FUN-1) antibody blocks the costimulatory activity of CD86 when tested in functional studies.

商品描述
2331 (FUN-1)
The 2331 (FUN-1) monoclonal antibody specifically recognizes a 75 kDa transmembrane cell surface protein, CD86 (B70/B7-2), expressed primarily on monocytes, dendritic cells and activated B cells. Competitive binding assays demonstrate that, while both 2331 (FUN-1) and IT2.2 (Anti-CD86) antibodies specifically recognize the same molecule, they react with different epitopes. CD86 is a ligand for CD28 and CTLA-4 and plays an important role in costimulation of T cells in primary immune response. The 2331 (FUN-1) antibody blocks the costimulatory activity of CD86 when tested in functional studies.

同种型
Mouse BALB/c IgG1, κ

克隆号
克隆 2331 (FUN-1) (RUO)

产品详情
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.

PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
应用
实验应用
Flow cytometry (Routinely Tested)

推荐用量
20 µl

反应种属
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)

目标/特异性
CD86 (B7-2)

背景
别名
B7.2; B7-2; B-lymphocyte activation antigen B7-2; B70; BU63; CD28LG2; LAB72

制备和贮存
存储溶液
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.

保存方式
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
文献
文献
研发参考(5)
1. Azuma H, Uno Y, Shigekiyo T, Saito S. Congenital plasminogen deficiency caused by a Ser572 to Pro mutation. Blood. 1993; 82(2):475-480. (Biology).
2. Engel P, Gribben JG, Freeman GJ, et al. The B7-2 (B70) costimulatory molecule expressed by monocytes and activated B lymphocytes is the CD86 differentiation antigen. Blood. 1994; 84(5):1402-1407. (Biology).
3. Engel P, Wagner N, Tedder TF. CD86 Workshop Report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:703-705.
4. Nozawa Y, Wachi E, Tominaga K, Abe M, Wakasa H. A novel monoclonal antibody (FUN-1) identifies an activation antigen in cells of the B-cell lineage and Reed-Sternberg cells. J Pathol. 1993; 169(3):309-315. (Clone-specific).
5. Yang XF, Chen Z, Wormsley SB. Nashville: American Society of Hematology; 1994.

数据库链接
Entrez-Gene ID
942

参考图片
Flow cytometric analysis of CD86 expression on Daudi cells. Daudi cells were either stained with PE Mouse Anti-Human CD86 (Cat. No. 555658/557344/560957; solid line histogram) or PE Mouse IgG1 κ Isotype Control (Cat. No. 555749; dashed line histogram). Fluorescent histograms were derived from gated events with the side and forward light-scattering characteristics of viable cells. Flow cytometry was performed on a BD FACScan™ system.