Corticosterone Assay (1 Kit)
1/4

Corticosterone Assay (1 Kit)

分享
品牌: R&D Systems
pdf 下载产品说明书
pdf 下载SDS
用小程序,查商品更便捷
收藏
对比对比
咨询咨询
    产品介绍
    产品信息
    产品详情

    Product Summary

    The Parameter Corticosterone assay is a 3.5 hour competitive enzyme immunoassay designed to measure Corticosterone in cell culture supernates, serum, plasma, and urine.

    Precision

    Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision
    Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of kit components

    Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine

    Intra-Assay PrecisionInter-Assay Precision
    Sample123123
    n202020202020
    Mean (ng/mL)1.243.988.051.394.088.21
    Standard Deviation0.0780.1790.6050.0990.2410.462
    CV%6.34.57.57.15.95.6

    Recovery

    The recovery of Corticosterone spiked to levels throughout the range of the assay in various matrices was evaluated.

    Sample TypeAverage % RecoveryRange %
    Cell Culture Media (n=4)114107-124
    Human EDTA Plasma (n=4)10887-127
    Human Heparin Plasma (n=4)10797-122
    Human Serum (n=4)11092-130
    Mouse EDTA Plasma (n=4)10496-111
    Mouse Serum (n=4)9679-113
    Rat EDTA Plasma (n=4)9877-114
    Rat Serum (n=4)9987-108
    Urine (n=4)10592-121

    Linearity

    To assess the linearity of the assay, samples containing and/or spiked with high concentrations of Corticosterone were diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.
    Multi-species Corticosterone ELISA Linearity
    Multi-species Corticosterone ELISA Linearity
    Multi-species Corticosterone ELISA Linearity

    Scientific Data

    Multi-species Corticosterone ELISA Standard Curve

    Assay Procedure

    Refer to the product for complete assay procedure.

    Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.
    1.   Prepare all reagents, standard dilutions, and samples as directed in the product insert.
    2.   Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.

    3. 50 µL Primary Antibody Solution
    4.   Add 50 µL of Primary Antibody Solution to all wells except the non-specific binding (NSB) wells. Cover with a plate sealer, and incubate at room temperature for 1 hour on a horizontal orbital microplate shaker.
    5.   Aspirate each well of the microplate and wash, repeating the process 3 times for a total of 4 washes.

    6. 100 µL Pretreatment F
    7.   Add 100 µL of Pretreatment F to all wells.

    8. 50 µL Standard, Control, or Sample
    9.   Add 50 µL of Standard, control, or sample to the appropriate wells.

    10. 50 µL of Calibrator Diluent
    11.   Add 50 µL of the Calibrator Diluent to the NSB and zero standard (B0) wells.

    12. 50 µL Conjugate
    13.   Add 50 µL of Conjugate to all wells. Cover with a new plate sealer, and incubate at room temperature for 2 hours on the shaker.
    14.   Aspirate and wash 4 times.

    15. 200 µL Substrate Solution
    16. Add 200 µL Substrate Solution to each well. Incubate at room temperature for 30 minutes on the benchtop. PROTECT FROM LIGHT.

    17. 100 µL Stop Solution
    18. Add 100 µL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm.

    Corticosterone Parameter Assay Kit Summary

    Format
    96-well strip plate
    Assay Length
    3.5 hours
    Sample Type & Volume Required Per Well
    Cell Culture Supernates (50 uL), Serum (50 uL), EDTA Plasma (50 uL), Heparin Plasma (50 uL), Urine (10 uL)
    Sensitivity
    0.047 ng/mL
    Assay Range
    0.1 - 25 ng/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine)
    Specificity
    Corticosterone in human, mouse, and rat samples.
    Cross-reactivity
    < 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
    Interference
    No significant interference observed with available related molecules.
    背景
    别名
    17-Deoxycortisol,C21H30O4,Corticosterone
    背景

    Background: Corticosterone

    Corticosterone, also known as Kendall's compound B and Reichstein substance B, is a glucocorticoid secreted by the adrenal gland cortex. It is produced in response to adrenal cortex stimulation by adrenocorticotropic hormone (ACTH) and is the precursor of aldosterone. Stress increases corticosteroid production. Corticosterone level is measured as an indicator of stress in patients with dietary restrictions, long-term memory impairment, and burn injuries.

    Alternate Names:
    17-Deoxycortisol;C21H30O4; Corticosterone
    研究领域
    制备和贮存
    保存方式

    Preparation and Storage

    Shipping
    The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.
    Storage
    Store the unopened product at 2 - 8 °C. Do not use past expiration date.
    声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。
    货号:
    KGE009
    一键复制
    询价
    1Kit
    选择数量
    当前规格1件起购 
    配送至
    预计2-3周送达,快递: 免运费,若需干冰额外收费